Commercial RO Membrane

Commercial RO Membrane

Commercial Ro membranes are designed to treat large volumes of water on a continuous basis. They are designed to withstand heavy use and effectively remove a wide range of contaminants, including minerals, salts and impurities.
Send Inquiry
Proshare Innovation Suzhou Co.,Ltd

 

Proshare Innovation Suzhou focuses on the realization of the third generation of Nano-composite thin film type high-end reverse osmosis and nanofiltration membrane TFN R & D and production, in the past 10 years has achieved rapid development, alternative to imported membrane products, stable application in textile wastewater, garbage leachate, high salt and high COD wastewater, and related environmental protection fields. PSI products can be widely used in industrial wastewater treatment, desalination, and pure water production, such as electric power, steel, electronics, electroplating, landfill leachate, petrochemicals, coal chemicals, thermal power, textile printing and dyeing, pulp and paper, pharmaceuticals, municipal drinking water treatment, biochemical technology, foods & beverages, aerospace and so on.

Why Choose Us

Our Factory

Proshare Innovation Suzhou focuses on the realization of the third generation of Nano-composite thin film type high-end reverse osmosis and nanofiltration membrane TFN R & D and production, in the past 10 years has achieved rapid development, alternative to imported membrane products, stable application in textile wastewater, garbage leachate, high salt and high COD wastewater, and related environmental protection fields.

Widely used

PSI products can be widely used in industrial wastewater treatment, desalination, and pure water production, such as electric power, steel, electronics, electroplating, landfill leachate, petrochemicals, coal chemicals, thermal power, textile printing and dyeing, pulp and paper, pharmaceuticals, municipal drinking water treatment, biochemical technology, foods & beverages, aerospace and so on.

Our Product

Reverse Osmosis Membrane Element, NF Membrane elements, Nanofiltration Membrane Element, Loose Nanofiltration Membrane Element, Compact Ultrafiltration Membrane Element, Special Membrane Element for Industry, Brackish Water Osmosis Membrane Element, Desalination RO Membrane Element, Ultra-Low Pressure Osmosis Membrane Element, Water Treatment Equipment and System, Anti-Fouling RO Membrane Elements.

Our Certificate

ROHS COMPLIANCE certificate, IS09001 quality system certificate, Environmental
management system certificate, health safety management system Certificate, Utility model patent certificate, Invention patent of multi-layer RO membrane, Invention patent of membranes produce.

 

 

 

Seawater Desalination Membrane Element

Seawater Desalination Membrane Element

Pro-SW Feature: The unique anti-fouling membrane technology gives excellent anti-fouling ability and washable performance, ensuring high salt-cutting performance while reducing energy consumption and prolonging the cleaning cycle.

Brackish Water Membrane Element

Brackish Water Membrane Element

Pro-BW Feature: The unique anti-fouling membrane technology gives excellent anti-fouling ability and washable performance, ensuring high salt-cutting performance while reducing energy consumption and prolonging the cleaning cycle.

Ultra-low Pressure Membrane Element

Ultra-Low Pressure Membrane Element

Pro-LP Features: PSl MEMBRANE® Pro-LP ultra-low pressure reverse osmosis membrane element is based on the latest Thin Film Nanocomposite (TFN)Technology, which achieves high flux at ultra-low operating pressure and leads to cost down.

Extreme Anti-fouling Membrane Element

Extreme Anti-Fouling Membrane Element

Pro-XFR Features: PSI MEMBRANE® Pro-XFR anti-fouling membrane is a third-generation Nano-composite membrane type(TFN)reverse osmosis membrane element the unique anti-fouling membrane technology gives excellent anti-fouling ability and clean ability, ensures high salt interception performance while reducing energy consumption and prolonging cleaning cycle.

Anti-fouling Membrane Element

Anti-Fouling Membrane Element

Pro-FR Feature: The unique anti-fouling membrane technology gives excellent anti-fouling ability and washable performance, ensuring high salt-cutting performance while reducing energy consumption and prolonging the cleaning cycle.

Domestic Reverse Osmosis Membrane

Domestic Reverse Osmosis Membrane

Our Reverse Osmosis membrane can remove up to 99% of over 1,000 contaminants from your water, including lead (removes up to 98% of lead), chlorine, fluoride, arsenic, asbestos, calcium, sodium, and more.

 

What is Commercial RO Membrane

 

 

Commercial Ro membranes are designed to treat large volumes of water on a continuous basis. They are designed to withstand heavy use and effectively remove a wide range of contaminants, including minerals, salts and impurities. Commercial ro membranes typically have larger surface areas and higher flow rates to provide efficient water treatment for applications such as restaurants, hotels, industrial facilities and large water purification plants.

 

Commercial RO Membrane

 

Advantages of Commercial RO Membrane

Commercial RO membrane has the ability to treat high TDS-level water.
Commercial RO membrane chances of fouling are very less.
Commercial RO membrane is very simple and can be easily operated.
Commercial RO membrane is also used to remove impurities in Food & Beverage Industry.
Commercial RO membrane is used to remove TDS in Industrial process water treatment.
Commercial RO membrane maintenance is negligible.
Commercial RO membrane price is cost-effective for their service life.

 

What Is the Difference Between Industrial and Commercial RO Membrane
 

Application: Commercial RO membranes are designed for small-scale water treatment applications such as in restaurants, cafes, and small businesses. They are also used in residential applications. On the other hand, industrial RO membranes are designed for large-scale water treatment applications such as in power generation, food and beverage manufacturing, and pharmaceutical production.

 

Water Quality: Commercial RO membranes are designed to treat water with low levels of impurities and dissolved solids, while industrial RO membranes are designed to treat water with high levels of impurities and dissolved solids. Industrial RO membranes can remove a wider range of contaminants including bacteria, viruses, and organic compounds.

 

Size: Commercial RO membranes are relatively small, with typical dimensions of 2 inches in diameter and 18 inches in length. Industrial RO membranes are larger, with typical dimensions of 4 inches in diameter and 40 inches in length.

 

Membrane Thickness: Industrial RO membranes are made of thicker TFC material than commercial RO membranes, typically ranging from 10 to 100 microns in thickness. Commercial RO membranes are made of thinner TFC material.

 

Performance: Industrial RO membranes have a higher salt rejection rate, typically ranging from 98 to 99.5%, compared to commercial RO membranes, which typically have a salt rejection rate of 95 to 98%. Industrial RO membranes are also more resistant to fouling and scaling, which can cause performance issues over time.

 

Operating Pressure: Commercial RO membranes are designed to operate at low pressure, typically around 150 psi, while industrial RO membranes are designed to operate at higher pressure, typically around 600 to 1000 psi.

 

Flow Rate: Commercial RO membranes have a lower flow rate, typically around 100 to 400 gallons per day (GPD), while industrial RO membranes have a higher flow rate, typically around 10,000 to 50,000 GPD.

 

Design: Commercial RO membranes are typically a single membrane element, while industrial RO membranes are comprised of several membrane elements assembled in a pressure vessel. The pressure vessel is designed to withstand high pressure and has multiple ports for the inlet and outlet water and the concentrate (waste) water.

 

Cost: Industrial RO membranes are more expensive than commercial RO membranes, due to their larger size, thicker TFC material, and higher performance. However, they are more cost-effective in large-scale applications, as they can treat a higher volume of water with lower operating costs.

 

Types of Commercial RO Membrane
Commercial RO Membrane
PROSHA~1
PROSHA~3
PROSHA~4

Thin-Film Composite (TFC) Membranes
Thin-film composite membranes are the most widely used and popular type of RO membranes. They consist of a thin, dense polyamide (PA) layer on top of a porous support layer. The polyamide layer is responsible for the rejection of salts and other dissolved impurities, while the support layer provides mechanical strength. TFC membranes offer high rejection rates and are known for their efficiency and durability.
Thin film composite (TFC) membranes are an essential component of various separation processes, especially in the field of desalination and water purification. These membranes are designed to have a highly selective barrier layer that enables the separation of different components, such as ions or molecules, based on their size and charge.

 

Cellulose Acetate (CA) Membranes
Cellulose acetate membranes were one of the first types of RO membranes developed. They consist of a cellulose-based material, a synthetic derivative of natural cellulose found in plants, coated on a non-woven fabric. CA membranes have lower rejection rates compared to TFC membranes and are more susceptible to fouling. But they can be used in certain applications where high salt rejection is not critical.
Cellulose acetate membranes are used in various separation processes, especially in applications like water treatment, filtration, and dialysis.

 

Polyamide Thin-Film (PA-TF) Membranes
Polyamide thin-film membranes are similar to TFC membranes, but use a different type of polyamide layer. PA-TF membranes are known for their high salt rejection rates and good overall performance in RO systems.
They are used in various separation processes, particularly in applications requiring high-temperature stability, chemical resistance, and selectivity. Polyimides are a group of synthetic polymers known for their exceptional thermal and mechanical properties.

 

Fully Aromatic Polyamide (FA) Membranes
Fully aromatic polyamide membranes are a type of PA-TF membrane made from fully aromatic polyamide materials. These membranes offer higher chlorine tolerance and can be used in water with higher chlorine concentrations without degradation.

Fully aromatic polyimide membranes are used in membrane separation processes due to their exceptional properties such as high thermal stability, chemical resistance, and selectivity. These membranes are widely employed in applications that require stringent separation requirements and harsh operating conditions.

 

Nanocomposite Membranes
Nanocomposite RO membranes incorporate nanomaterials, such as nanoparticles or nanotubes, into the polyamide layer to achieve enhanced properties and performance compared to traditional membranes. These nanomaterials can enhance membrane properties, such as salt rejection, permeability, and fouling resistance.

 

Spiral-Wound Membranes
Spiral-wound membranes are the most common configuration for RO membranes. They consist of flat sheets of membrane material wrapped around a permeate collection tube to form a spiral-wound structure. The spiral-wound design allows for a large membrane surface area in a compact space, making it efficient for industrial-scale RO systems.

 

Hollow-Fiber Membranes
Hollow-fiber RO membranes are designed as small, tubular fibers with a hollow core that resemble tiny straws. These fibers are used to create a high surface area for separation. That allows fluid to flow both inside and outside of the fibers.

 

What Is the Life of a Commercial RO Membrane
 

Reverse osmosis membrane lifespan has often been seen to be between two and three years. However, there may be circumstances where a membrane continues, to function for up to five years. But, keep in mind that contaminated water will compel the membrane to prematurely degrade.
The system design, element selection, pretreatment, system operation, membrane cleaning, and system maintenance, all affect the lifespan of RO elements.
Foreign substances found in the feed water, such as calcium precipitates, organic and biological debris, and metal oxide hydrates, can foul the surface of a RO membrane. The term "fouling" refers to the accumulation of several layers, such as scaling and biofilm formation, on the membrane surface. 

Change of RO Membrane

Now, if you want to determine whether or not to replace the RO membrane, you need look at the TDS of the purified water. There is a strong likelihood that the membrane has to be changed if the TDS is rising.
Note that compared to the typical time limit of 2-3 years, excessive TDS and hard water may force you to change the membrane more regularly.

Replacement of RO Membrane

Approximately, 80% of the overall expense of a RO plant goes towards replacing the RO filters and RO membranes. This is so because the RO water purifier's replacement is its main component. We must say that you have compromised on the following items, if the RO plant's filters and membrane are damaged or of poor quality:
● Having access to water that is pure, clean, and safe.
● RO purification system quality and longevity are improved.
● Lowering the expense of upkeep.

 

How to Choose Commercial RO Membrane
 

Step 1: Determine Your Water Quality
The first step in selecting an commercial RO membrane is to determine your water quality. The quality of the feed water will determine the type of membrane required to achieve the desired water quality. The water quality can be assessed by conducting a water analysis to determine the concentration of impurities and contaminants present in the water. The water analysis report will provide valuable information such as the total dissolved solids (TDS) level, pH, and hardness of the water. This information is critical in determining the appropriate membrane configuration and size required to achieve the desired water quality.

 

Step 2: Identify Your System Requirements
The next step is to identify the requirements of your RO system. This includes determining the flow rate, pressure, and temperature of the feed water. The flow rate is the amount of water that the system is required to produce per day, and it is typically measured in gallons per day (GPD). The pressure and temperature of the feed water will determine the type of pump required to provide the necessary pressure to the commercial RO membrane. The system requirements will also determine the type of membrane configuration required, such as spiral-wound or hollow-fiber membranes.

 

Step 3: Determine the Membrane Configuration
There are several membrane configurations available for commercial RO membrane, including spiral-wound, hollow-fiber, and ceramic membranes. Spiral-wound membranes are the most commonly used in commercial RO systems due to their high efficiency, durability, and cost-effectiveness. Hollow-fiber membranes are ideal for systems with high flow rates and are commonly used in industrial applications. Ceramic membranes are used in applications where high-temperature and pressure are required, such as the treatment of wastewater.

 

Step 4: Choose the Membrane Material
Commercial RO membrane are available in several materials, including cellulose acetate, polyamide, and thin-film composite (TFC). Cellulose acetate membranes are suitable for low TDS feed water and are less expensive than other membrane materials. Polyamide membranes are more durable and efficient than cellulose acetate membranes and are suitable for high TDS feed water. TFC membranes are the most efficient and durable of the three and are ideal for high TDS feed water.

 

Step 5: Determine the Membrane Size
The size of the commercial RO membrane required is dependent on the flow rate and the pressure of the feed water. The size of the membrane is typically measured in square feet and is determined by the system requirements. It is essential to choose the appropriate membrane size to ensure optimal system performance and to prevent membrane fouling.

 

 

 

How to Calculate Commercial RO Membrane Flux

Membrane Flux (J) = (Permeate Flow Rate) / (Membrane Area)
Permeate Flow Rate = The volume of permeate (the liquid that has passed through the membrane) produced per unit time.
Membrane Area = The area of the membrane surface through which the permeate flows.
To calculate the RO membrane flux, you can follow these steps:
Measure the permeate flow rate: Measure the volume of permeate that has passed through the membrane over a certain period of time. The flow rate can be calculated as follows:
Permeate Flow Rate = (Permeate Volume) / (Time)
Permeate Volume = The volume of permeate produced during the measurement period.
Time = The measurement period in seconds.
Measure the membrane area: Measure the area of the membrane surface that is in contact with the liquid being filtered.
Calculate the membrane flux: Use the formula above to calculate the membrane flux by dividing the permeate flow rate by the membrane area.
Membrane Flux (J) = (Permeate Flow Rate) / (Membrane Area)
Note: The units of measurement for the permeate flow rate and membrane area must be consistent. For example, if the permeate flow rate is measured in liters per hour, the membrane area should be measured in square meters. This was our news update this week from HID membranes and we hope this information we be useful to you. Have a lovely week.

PROSHA~1

 

How to Store Commercial RO Membrane

 

 

New film (before use)
①The membrane element must always be kept in a wet state. Even when it is necessary to temporarily open the same package to confirm the quantity of the same package, it must be in a state without puncturing the plastic bag. This state should be stored until the time of use.
②When storing in an atmosphere over 10℃, avoid direct sunlight and choose a well-ventilated place. At this time, the storage temperature should not exceed 35°C.
③If it freezes, it will be physically damaged, so take heat preservation measures and don't freeze it.

 

Membrane element after passing water
①The membrane element must be kept in a dark place at all times, the storage temperature should not exceed 35℃, and direct sunlight should be avoided.
②It may freeze when the temperature is below 0℃, so anti-freezing measures should be taken.
③The composite series of membrane elements should be immersed in pure water or reverse osmosis filtered water containing stored chemicals (sodium bisulfite, 500-1000mg/L, pH 3-6).
④ When storing under any circumstances, the membrane should not be kept in a dry state.
⑤ The concentration and pH value of the preservation solution must be kept within the above range, and regular inspections are required. If it may deviate from the above range, prepare the preservation solution again.

 

 
FAQ
 
 

Q: How do I know if my commercial RO membrane is good or bad?

A: The most practical way to evaluate the performance of a commercial RO membrane and its water quality is through electrical conductivity. In reality, pure water is a poor conductor of electricity. Water's conductivity is based on the concentration of ionized compounds (salts, acids, or bases) that are dissolved in it.

Q: How often should I flush commercial RO membrane?

A: At a minimum, the commercial RO membrane should be flushed at the end of each work day, but it's better to do it after every use. Without flushing, the commercial RO membrane can also become moldy, which will create additional blockages.

Q: Are all commercial RO membranes the same?

A: These are very similar in construction and performance. Like other products, the main difference is in the reputation and reliability of the manufacturer. However, because there are different manufacturers, membranes do come in several end type configurations depending on the manufacturer.

Q: What is the maximum life of commercial RO membrane?

A: Generally, it has been observed that the Reverse Osmosis membrane lasts for about 2-3 years. However, there might be cases where membrane works for as long as five years. But remember, the water should not be challenging because it will force the Membrane to die early.

Q: What can harm an commercial RO membrane?

A: In addition to residual chlorine, other factors can contribute to membrane element degradation. These include high operating pressures, elevated temperatures, fouling from suspended solids or organic matter, and exposure to chemicals incompatible with the membrane material.

Q: What happens if the commercial RO membrane is not working?

A: When the RO is stopped or in stand-by, natural osmosis will happen between the permeate side and the concentrate side containing high salinity brine. This can damage the feed spacers by creating a vacuum in the permeate line, as water will naturally flow back to the concentrate side, driven by osmotic pressure.

Q: What is the working principle of commercial commercial RO membrane?

A: Reverse Osmosis (RO) works by reversing the principle of osmosis, the natural tendency of water with dissolved salts to flow through a membrane from lower to higher salt concentration. This process is found throughout nature. Plants use it to absorb water and nutrients from the soil.

Q: How to choose the best RO membrane?

A: If you are looking for a membrane that is designed to be more energy efficient, then you should consider a membrane with a thinner gauge. You should also consider the membrane's working temperature. A membrane with a higher working temperature will last longer, but it will also require more energy and water.

Q: How are commercial RO membranes rated?

A: RO systems are rated on how much water they can produce per day (gallons per day or GPD). GPD ratings are based on tests performed under optimal water conditions (specific water temperatures and contaminant levels to achieve highest production rating).

Q: What is the requirement of a commercial RO membrane?

A: The RO process involves the use of a semi-permeable membrane that separates dissolved salts, organic molecules, and other impurities from water. In a typical RO system, the membrane is arranged in a series of modules, and the number of modules required depends on the water flow rate and the quality of the feed water.

Hot Tags: commercial ro membrane, China commercial ro membrane manufacturers, suppliers, factory, commercial Reverse Osmosis Membranes element, thin film Reverse Osmosis Membranes filter, high recovery Reverse Osmosis Membranes element, RO Reverse Osmosis Membranes membrane, thin film Reverse Osmosis Membranes membrane, thin film Reverse Osmosis Membranes element