Domestic Reverse Osmosis Membrane

Domestic Reverse Osmosis Membrane

Our Reverse Osmosis membrane can remove up to 99% of over 1,000 contaminants from your water, including lead (removes up to 98% of lead), chlorine, fluoride, arsenic, asbestos, calcium, sodium, and more.
Send Inquiry

Pro-ULP Domestic RO Membrane – Ultra-Low Pressure High-Flux Solution for Drinking Water

PSI MEMBRANE® Pro-ULP Series Domestic RO Membrane is an ultra-low pressure domestic reverse osmosis membrane designed for residential drinking water purification and light commercial use.
This advanced domestic RO membrane delivers significantly higher water flux under ultra-low operating pressure, ensuring pure, safe, and great-tasting drinking water while reducing energy consumption.


Key Features & Benefits of Pro-ULP Domestic RO Membrane

1. 30% higher flux for domestic RO systems
The Pro-ULP domestic RO membrane enhances permeate flow by up to 30%, providing faster water production and improved efficiency in home RO water purifier systems.

2. Reliable performance with long-term cost efficiency
Engineered for durability, this domestic reverse osmosis membrane offers stable long-term operation with reduced maintenance and replacement frequency, delivering excellent cost-effectiveness for household users.

3. Stable operation across a wide TDS range
The Pro-ULP domestic RO membrane performs consistently across a wide range of feed water TDS levels, with slow flux decline and stable salt rejection. This makes it suitable for variable municipal water sources and mixed household water conditions.

4. Flexible customization for domestic RO markets
To meet diverse market and branding needs, the Pro-ULP domestic RO membrane supports customization in flux rating, membrane color, and packaging, making it ideal for OEM, ODM, and private-label domestic RO membrane solutions.


Typical Applications

Home RO water purifiers

Under-sink and countertop RO systems

Residential drinking water treatment

Light commercial water dispensers

OEM domestic RO system manufacturers

 

Product Parameters

 

Product

Average Permeate Flow
GPD (m³/d)

Average Salt Rejection %

Test conditions

NaCl

Pressure

Temperature

pH

Recovery Rate

Pro-ULP-1812-50

≥50(0.19)

≥97.0

350mg/L

70psi

25℃

6.5~7.5

15%

Pro-ULP-1812-75

≥75(0.29)

≥97.0

350mg/L

70psi

25℃

6.5~7.5

15%

Pro-ULP-2012-100

≥100(0.38)

≥97.0

350mg/L

70psi

25℃

6.5~7.5

15%

Pro-ULP-2012-150

≥150(0.57)

≥97.0

350mg/L

70psi

25℃

6.5~7.5

15%

Pro-ULP-2812-300

≥300(1.14)

≥97.0

350mg/L

70psi

25℃

6.5~7.5

15%

Pro-ULP-3012-400

≥400(1.52)

≥97.0

350mg/L

70psi

25℃

6.5~7.5

15%

Pro-ULP-3012-600 ≥600(2.28) ≥97.0 350mg/L 70psi 25℃ 6.5~7.5 15%

Pro-ULP-3013-400

≥400(1.52)

≥97.0

350mg/L

70psi

25℃

6.5~7.5

15%

Pro-ULP-3013-500

≥500(1.90)

≥97.0

350mg/L

70psi

25℃

6.5~7.5

15%

Pro-ULP-3013-600

≥600(2.28)

≥97.0

350mg/L

70psi

25℃

6.5~7.5

15%

Pro-ULP-3113-800 ≥800(3.04) ≥97.0 350mg/L 70psi 25℃ 6.5~7.5 15%
Pro-ULP-3213-1000 ≥1000(3.80) ≥97.0 350mg/L 70psi 25℃ 6.5~7.5 15%

 

The stated product performance is based on data taken after 30 minutes of operation at the following test Conditions: 250 ppm NaCl,test pressure of 60 psifor <400 GPD, and test pressure of 90 psi for ≥400 GPD; 15% recovery; 77℉ (25℃); pH 6.5–7.0; Permeate flow rate for each element may vary +15 / -15%; All elements are vacuum leak tested using the Proshare integrity test; Elements can be supplied as dry or wet-type. Wet-tested elements are soaked in a preservative solution (1.0% food grade SBS) and vacuum sealed in a poly bag. All elements are individually boxed.

 

SIZE: mm/Inch

Model

A
Inch
(mm )

B
Inch
(mm )

C
Inch
(mm )

D
Inch
(mm )

E
Inch
(mm )

Pro-LP-1812-75

1.75
(44.5)

0.72
(18.2)

0.87
(22.0)

0.87
(22.0)

12.00
(297.5)

Pro-LP-2012-100

1.81
(46.0)

0.72
(18.2)

0.87
(22.0)

0.87
(22.0)

12.00
(297.5)

Pro-LP-2812-300

2.68
(46.0)

0.72
(18.2)

0.87
(22.0)

0.87
(22.0)

12.00
(297.5)

Pro-LP-3012-400

2.91
(74.0)

2.91
(74.0)

0.87
(22.0)

0.87
(22.0)

12.00
(298.5)

Pro-LP-3013-600

2.68
(68.0)

0.72
(18.2)

0.78
(20.0)

0.78
(20.0)

13.00
(333.0)

 

product-497-138

 

Recommended Operating Conditions

 

Operating Limits

Unit

Value

Maximum operating pressure

psi (MPa)

600(41)

Maximum feed water temperature

°F (°C)

113(45)

Continuous operation pH range

 

3-10

Cleaning PH range

 

2-11

Maximum feed water SDI15

 

5

Maximum residual chlorine concentration of influent

ppm

<0.1

 

General Handing Procedures

 

Store in a cool and dry place (below 45°C) away from sunlight.

Permeate from the first hour of operation should be discarded.

Keep elements moist at all times after initial wetting.

To prevent microbial growth in the Wet Membrane Element, it is recommended to wash it with a 1.0% Sodium Metabisulfite (food grade) solution, followed by vacuum-bag packing the
Membrane Element and storing it in a cardboard box.

Only use chemicals compatible with the membrane elements and components. Bright Star Water will not accept any responsibility for the use of incompatible chemicals.

 

Hot Tags: domestic reverse osmosis membrane, China domestic reverse osmosis membrane manufacturers, suppliers, factory, RO Membrane Cleaning, commercial Reverse Osmosis Membranes cartridge, desalination Reverse Osmosis Membranes housing, commercial Reverse Osmosis Membranes element, Domestic Reverse Osmosis Membrane, thin film Reverse Osmosis Membranes filter

Send Inquiry