
Compact Ultrafiltration Membrane Element
Proshare Innovation Suzhou focuses on the realization of the third generation of Nano-composite thin film type high-end reverse osmosis and nanofiltration membrane TFN R & D and production, in the past 10 years has achieved rapid development, alternative to imported membrane products, stable application in textile wastewater, garbage leachate, high salt and high COD wastewater, and related environmental protection fields. PSI products can be widely used in industrial wastewater treatment, desalination, and pure water production, such as electric power, steel, electronics, electroplating, landfill leachate, petrochemicals, coal chemicals, thermal power, textile printing and dyeing, pulp and paper, pharmaceuticals, municipal drinking water treatment, biochemical technology, foods & beverages, aerospace and so on.
Why Choose Us
Our Factory
Proshare Innovation Suzhou focuses on the realization of the third generation of Nano-composite thin film type high-end reverse osmosis and nanofiltration membrane TFN R & D and production, in the past 10 years has achieved rapid development, alternative to imported membrane products, stable application in textile wastewater, garbage leachate, high salt and high COD wastewater, and related environmental protection fields.
Widely used
PSI products can be widely used in industrial wastewater treatment, desalination, and pure water production, such as electric power, steel, electronics, electroplating, landfill leachate, petrochemicals, coal chemicals, thermal power, textile printing and dyeing, pulp and paper, pharmaceuticals, municipal drinking water treatment, biochemical technology, foods & beverages, aerospace and so on.
Our Product
Reverse Osmosis Membrane Element, NF Membrane elements, Nanofiltration Membrane Element, Loose Nanofiltration Membrane Element, Compact Ultrafiltration Membrane Element, Special Membrane Element for Industry, Brackish Water Osmosis Membrane Element, Desalination RO Membrane Element, Ultra-Low Pressure Osmosis Membrane Element, Water Treatment Equipment and System, Anti-Fouling RO Membrane Elements.
Our Certificate
ROHS COMPLIANCE certificate, IS09001 quality system certificate, Environmental
management system certificate, health safety management system Certificate, Utility model patent certificate, Invention patent of multi-layer RO membrane, Invention patent of membranes produce.
Loose Nanofiltration Membrane Element
The UNF series of Loose Nanofiltration or Compact Ultrafiltration Membrane elements adopt pro. proprietary multilayer composite membranes, The ultra-smooth and ultra-thin hydrophilic coating membrane technology with nano-level regulation gives excellent anti-pollution ability.
Nanofiltration Membrane Element
The Nanofiltration membrane element uses a proprietary multilayer composite membrane and nano-level regulation of ultra-thin hydrophilic coating membrane technology to provide excellent anti-pollution ability.
NF98 Series Multilayer Composite Membrane
NF98 series nanofiltration membrane element adopts proprietary multilayer composite mem-brane, Nano-level regulation of ultra-thin hydrophilic coating membrane technology to give excellent anti-pollution ability, at the same time, the flux is up to more than 2 times higher than the mainstream imported competing products and the operating pressure can be reduced by more than 50%, its performance comprehensively surpasses and can perfectly replace NF270, XC-N, DL, DK, and other traditional TFC nanofiltration membranes.
What is Compact Ultrafiltration Membrane Element
The compact ultrafiltration membrane elements use multilayer composite membranes that are professionally made. Excellent anti-pollution capacity is provided by the ultra-smooth and ultra-thin hydrophilic-coated membrane technology with nano-level modulation. The operating pressure can be lowered by more than 50% while maintaining a flux that is up to four times higher than that of major imported competitors' goods. The membrane outperforms and flawlessly substitutes the TFC ultrafiltration membranes from the SUEZ (GE) G series:1. A range of cutting molecules are available and can be tailored to meet the needs of the client. 2. A significant reduction in energy usage of up to four times the import flux of rival items and the project budget. 3. Extremely high selectivity separation performance: eliminate the majority of colloidal silicon humic and iron.
Advantages of Compact Ultrafiltration Membrane Element
High recovery rate
In fact, the main advantage of ultrafiltration membrane element is that its recovery rate is very high. In the process of use, it can effectively avoid waste of resources. Ultrafiltration membrane element with low recovery rate not only have poor performance during use, but also It will bring a huge economic burden to the enterprise.
There is no phase change in the treatment process
Some ultrafiltration membrane element, because of their poor performance, will produce phase changes during the treatment process. We need ultrafiltration membrane element that do not produce photos during use, so in this process, we can purchase them on the market. Ultrafiltration membrane element with a relatively high occupancy rate.
The production cycle is short
The main advantage of ultrafiltration membrane element is that its production cycle is short, it can be produced quickly, and it can help enterprises improve economic benefits. Therefore, in this process, we should also understand when purchasing ultrafiltration membrane element, precisely because of its production cycle. Short, so no bulk purchases are required.
Low energy consumption
Compared with other filtration membranes, ultrafiltration membrane element have the characteristics of low energy consumption, which is also one of the advantages of its use. It is precisely because of this that people mainly choose ultrafiltration membrane element in the process of purchasing similar products. This product, he can effectively reduce energy consumption.

Ultrafiltration membrane is a kind of filtration between microfiltration and nanofiltration, and is a membrane separation technology suitable for material separation, concentration and purification. It is generally characterized by molecular weight cutoff in practical applications, as long as it is used to separate macromolecules, colloids and particles in solution from small molecules such as solvents. The macromolecules, colloids and particles are trapped on the surface of the membrane, and the concentrated solution is carried away by the circulating flow of materials, so as to achieve the purpose of material separation, concentration and purification. The application fields of ultrafiltration mainly involve food, beverage, biomedicine, fine chemical industry, industrial wastewater treatment and reuse, etc.
Application field
Clarification and concentration of dairy products, fruit juices, vegetable juices, etc.
Extraction of active ingredients from animals and plants (aloe, mangosteen, tea, etc.)
Extraction and concentration of soybean protein, oligosaccharides, isoflavones, etc.
Purification and separation of antibiotics, amino acids, VC and other fermentation broths
Purification-Isolation of Active Components of Traditional Chinese Medicine (Bupleurum, Salvia, Scutellaria, etc.) Injection
Medical pure water sterilization, depyrogenation, drug concentration and separation
Purification and concentration of polysaccharides (Ganoderma lucidum, frondosa, shiitake, etc.)
Fluorescent whitening agent desalting and concentration
Electrophoretic paint recycling and water reuse
Reuse of PVA in textile desizing waste liquid, recovery of fiber processing oil, recovery of lanolin in wool scouring waste water
Semiconductor industry ultrapure water, integrated circuit cleaning water terminal treatment.
Water treatment engineering: mineral water preparation, drinking water purification, and ultrafiltration as pretreatment for reverse osmosis.
The influence of temperature on water production: The increase of temperature increases the activity of water molecules, and the viscosity decreases, so the water production increases. On the contrary, the water production is reduced, so the difference in water production between winter and summer is very large even for the same ultrafiltration system.
The influence of operating pressure on water production: In the low pressure section, the water production of the ultrafiltration membrane is proportional to the pressure, that is, the water production increases with the increase of the pressure, but when the pressure value exceeds 0.3MPa, even if the pressure increases The increase of water production is also very small, mainly because the ultrafiltration membrane is compressed under high pressure and the water permeability resistance is increased.
Influence of influent turbidity on water production: The greater the influent turbidity, the less water produced by the ultrafiltration membrane, and the greater the influent turbidity is more likely to cause blockage of the ultrafiltration membrane.
The influence of flow rate on water production: The influence of flow rate on water production is not as obvious as that of temperature and pressure. Too slow flow rate will easily lead to blockage of ultrafiltration membrane, and too fast will affect water production.
Compact ultrafiltration membrane element is a fine water treatment consumable. Relevant precautions for storage and stopping must be taken during daily use, such as storage precautions for unopened use, as well as precautions for stopping and storing. In use of uf membrane, it may be necessary to stop using it due to certain reasons. At this time, protection measures must also be taken; otherwise, the performance of uf membrane will be affected. Generally, it is divided into short-term storage and long-term storage. Short-term storage refers to stopping use no more than 10 days, and long-term storage refers to stopping use for more than 10 days. The storage methods for these two situations are as follows.
Short-term storage: Before stopping the use, the compact ultrafiltration membrane element should be sterilized and backwashed once, and then pure water should be injected into the membrane element. After that, the inlet valve, outlet valve and regulating valve of the uf membrane should be closed to achieve sealing and sterilization effects, effectively preventing the membrane element from being contaminated by impurities such as bacteria, organic matter, and microorganisms.
Long-term storage: The compact ultrafiltration membrane element should also be disinfected and backwashed before stopping the use. The difference is that after cleaning, a protection solution (usually made up of water: glycerin: sodium bisulfite = 79:20:1) should be injected, and then sealed for storage.
During storage, if it is necessary to move the compact ultrafiltration membrane element, it should be handled gently to avoid collision with other objects, so as not to damage the outer shell and membrane of uf membrane. Generally, manufacturers will add protection solution in the packaging and the temperature should be kept between 5 and 40°C during storage. In general, storage for less than 6 months is not a problem.

Process of Compact Ultrafiltration Membrane Element in Water Treatment
When the water contains microorganisms, after entering the pre-treatment system, some of the trapped microorganisms may adhere to the pre-treatment system, such as the media surface of a multi-media filter. When adhering to the surface of the ultrafiltration membrane, it grows and reproduces, which may completely block the micropores, or even completely block the cavity of the hollow fiber. The existence of microorganisms is extremely harmful to the hollow fiber ultrafiltration membrane. Attention must be paid to removing bacteria and algae in raw water. In water treatment projects, oxidants such as NaClO and O 3 are usually added, and the concentration is generally 1 to 5 mg/l. In addition, UV sterilization can also be used. The hollow fiber ultrafiltration membrane module is sterilized in the laboratory, and it can be treated with hydrogen peroxide (H 2 O 2) or potassium permanganate aqueous solution for 30 to 60 minutes. The microbe-killing treatment can only kill microbes, but it cannot remove microbes from the water, but only prevents the growth of microbes.
When the water contains suspended matter, colloids, microorganisms and other impurities, it will cause the water to produce a certain degree of turbidity. The turbidity will hinder the transmission of light. This optical effect is related to the amount, size and shape of the impurities. The turbidity of water is measured by corrosion degree, and the turbidity produced by 1mg/lSiO 2 is 1 degree. The higher the degree, the more impurity content. There are different requirements for water supply turbidity in different fields. For example, for general domestic water, the turbidity should not be greater than 5 degrees. Since turbidity is measured by passing light through the raw water to measure the amount of light reflected by the particles in the water, the color and opacity, the size, number and shape of the particles all affect the measurement, and the relationship between turbidity and suspended solids is random. For particles smaller than a few microns, turbidity cannot be reflected.
For impurities with a particle size of 5 μm or more, a filter with a filtration accuracy of 5 μm can be used to remove, but for fine particles and colloids between 0.3 to 5 μm, it is difficult to remove them using the above-mentioned conventional filtration technology. Although ultrafiltration can absolutely remove these particles and colloids, it is extremely harmful to hollow fiber ultrafiltration membranes. In particular, colloidal particles are charged, which is a polymer of material molecules and ions, so colloids can exist stably in water, mainly because colloidal particles of the same charge repel each other. Add a charged substance (flocculant) that has the opposite electrical properties of the colloidal particles to the raw water to break the stability of the colloidal particles, neutralize the charged colloidal particles to neutrality, and make the dispersed colloidal particles agglomerate into large agglomerates , And then can be easily removed by filtration or sedimentation.
Soluble organic matter cannot be completely removed by flocculation sedimentation, multi-media filtration and ultrafiltration. At present, the oxidation method or the absorption method is mostly used.
● The oxidation method uses chlorine or sodium hypochlorite (NaClO) for oxidation, which has a better effect on removing soluble organic matter. In addition, ozone (O 3) and potassium permanganate (KMnO 4) are also better oxidants, but the cost is slightly higher.
● Adsorption method The use of activated carbon or macroporous adsorption resin can effectively remove soluble organic matter. However, oxidation treatment is still needed for alcohols and phenols that are difficult to adsorb.
● Adjustment of water supply temperature
The water permeability of the ultrafiltration membrane is directly related to the temperature. The calibrated water permeability of the ultrafiltration membrane module is generally tested with pure water at 25 ℃. The water permeability of the ultrafiltration membrane is proportional to the temperature, and the temperature coefficient is about It is 0.02/1 ℃, that is, for every 1 ℃ increase in temperature, the water permeation rate will increase by approximately 2.0%. Therefore, when the temperature of the water supply is low (such as <5 ℃), some kind of heating measures can be adopted to make it run at a higher temperature to improve work efficiency. However, when the temperature is too high, it is also unfavorable to the membrane and will cause changes in membrane performance. For this, cooling measures can be used to reduce the temperature of the water supply.
Cleaning Method of Compact Ultrafiltration Membrane Element
Physical method: Generally, filters with a pore size of 5~10 μm are installed before ultrafiltration to remove solid suspended solids and colloids such as iron and aluminum. The fouled membrane can be cleaned by the following methods.
Hydraulic method, reducing the operating pressure and increasing the circulating volume of the retained liquid (ie high-speed water flushing) is conducive to increasing the flux; the use of liquid flow pulses can quickly remove membrane fouling, especially the combination of washing liquid pulses and recoil, Satisfactory results will be obtained. For example, the internal pressure type hollow fiber membrane can be cleaned in the following two ways. One is to backflush the washing liquid through the membrane in reverse to remove the dirt deposited on the inner wall of the fiber. Note that the washing liquid must not contain suspended matter to prevent the spongy bottom layer of the hollow fiber membrane from being blocked. For example, two ultrafilters can be run in parallel during backwashing, and the effluent of one ultrafilter can be used to backwash the other ultrafilter. This should be performed at a lower operating pressure to avoid membrane rupture. The backwashing time It usually takes 20 to 30 minutes. The other is to close the outlet of the permeate by circulating washing, and use the feed liquid and the permeate for cleaning. Since the flow rate of the feed liquid in the hollow fiber cavity is high, the flow pressure drop is large. After closing the outlet of the permeate, the pressure between the fibers is roughly equal to the average value of the pressure in the fibers. The inner pressure of the inlet section of the hollow fiber is higher, resulting in filtrate; the outer pressure of the outlet section of the fiber is higher, and the filtrate flows back into the fiber. In the inner cavity, the permeate circulates inside and outside the hollow fiber. The returned filtrate flow and the high-speed feed liquid flow can remove the deposited dirt. Recently, a development trend is to use two sets of internal pressure hollow fiber membranes in combination. Ultrafiltrate is used to backflush another set of hollow fiber membranes, and the exchange is carried out after a period of time. Generally, it is working for 10 minutes and backflushing for 1min.
This method of backflushing while working can well prevent the blockage of the membrane pores and make the membrane pass through. Keep working at a high level. This method of operation breaks through the view that it is necessary to wait until the membrane is fouled before it stops working for cleaning. It does not need cleaning agents and does not need to remove the membrane assembly. It is a very good method. The control part of the switch has higher requirements, otherwise the life of the membrane will be affected.
For another example, the external pressure hollow fiber membrane can be washed by the isobaric method. When flushing, the first step is to depressurize operation, close the ultrafiltrate outlet and increase the flow rate of the raw solution inlet. At this time, the inner cavity pressure of the hollow fiber rises until it reaches the same operating pressure as the outer cavity of the fiber, so that the pressure difference between the inner and outer sides of the membrane is zero, and the retention The solute molecules on the membrane surface will be suspended in the solution and discharged with the concentrated water.
Isobaric flushing is suitable for hollow fiber membranes. For hollow fiber membrane modules, the negative pressure cleaning method can also be used, that is, the functional surface of the membrane is in a negative pressure state by means of suction, so as to remove pollutants and restore the performance of the membrane. The advantage is that when the outside pressure of the membrane is atmospheric pressure, the maximum pressure difference between the inside and outside of the membrane is one atmospheric pressure, the membrane is not easily damaged, and its cleaning effect is better than isobaric cleaning.
Gas-liquid pulses pass high-pressure gas (air or nitrogen) into the gap of the membrane filter device to form gas-liquid pulses. The gas pulse expands the pores in the membrane, allowing contaminants to be flushed away by the liquid. The effect of this method is good, and the gas pressure is generally 0.2~0.5MPa, which can restore the membrane flux to more than 90%. In addition, there are electric field filtration, pulse electric pulse cleaning, pulse electrolytic cleaning, electro-osmosis backwashing, sponge ball mechanical scrubbing and other methods.
FAQ
Hot Tags: compact ultrafiltration membrane element, China compact ultrafiltration membrane element manufacturers, suppliers, factory, ultrafiltration membrane, Compact Ultrafiltration Membrane Element, Water Treatment Membrane, Loose Nanofiltration Membrane Element
You Might Also Like
Send Inquiry








